In this video, we’ll discuss how to determine if ultraviolet (UV) light is effectively disinfecting a space. A dosimeter, a small card with UV-sensitive ink, is commonly used. It changes color when exposed to UV light, providing a visual indication of the UV dose received.
The dosimeter is calibrated to respond to the specific wavelength of UV light emitted by germicidal UV fixtures, typically 254 nanometers. The color change on the dosimeter corresponds to different levels of UV exposure, measured in millijoules per square centimeter (mJ/cm²).
By comparing the color change on the dosimeter to laboratory studies, we can determine the level of disinfection achieved. Different pathogens, such as bacteria and viruses, have varying sensitivities to UV light. Studies have shown that specific UV doses are required to kill or deactivate these microorganisms.
Using a dosimeter ensures that the UV light is delivering the necessary dose to disinfect the target area. It provides tangible evidence that the UV system is effectively eliminating pathogens, helping to maintain a clean and hygienic environment.